OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM 2-pole, 30-amp definite purpose contactor (ICP part #1178074, CONTACTOR 2P 30A 24V) is the main switching relay for the ICP/Tempstar/Heil RHS060S0CB0AAA condensing unit. When the thermostat calls for cooling, the 24-volt coil energizes and pulls the contacts closed, sending line voltage to the compressor and condenser fan motor. Contactors are high-wear parts: their silver contacts pit, burn, and weld over thousands of cycles. A failing contactor causes a no-cool condition, chattering or buzzing, contacts that stick closed (compressor won't shut off), or contacts that won't pull in at all. Replacing a worn 30A contactor restores reliable, clean switching and protects the compressor from voltage drop and arcing damage.
| Spec | Value |
|---|---|
| Part Number | 1178074 |
| Type | Definite purpose contactor, 2-pole |
| Brand | ICP (Tempstar / Heil / Comfortmaker) |
| Contact Rating | 30 Amps |
| Coil Voltage | 24 VAC |
| Poles | 2 |
| Fit | OEM replacement |
Built for the ICP RHS060S0CB0AAA and shared ICP/Tempstar/Heil/Comfortmaker condensing units calling for a 2-pole 30A 24V coil contactor. Verify your original coil voltage is 24V and contact rating is 30A before installing.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.