Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RHS048S0XA0AAAA — 24V Coil 30 Amp | Ships Today
ICP

ICP 2-Pole 30A Contactor for RHS048S0XA0AAAA — 24V Coil 30 Amp | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole 30-amp contactor (part #1178074) is the main power-switching relay for your ICP RHS048S0XA0AAAA condensing unit. Its 24V coil is energized by the thermostat through the control circuit; when energized, the two pole contacts close and feed line voltage to the compressor and condenser fan motor. Contactors are high-wear parts — the contacts arc each time they open and close, and over thousands of cycles they pit, burn, or weld. Burnt contacts cause hard starts, chattering, or a unit that runs nonstop; a welded contactor keeps the compressor energized even after the thermostat is satisfied.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole
Contact Rating 30 Amp
Coil Voltage 24V
Fitment OEM Replacement

Compatibility

Fits the ICP RHS048S0XA0AAAA and other Tempstar, Heil, and Comfortmaker condensing units that use a 2-pole, 30A, 24V-coil definite purpose contactor. Verify pole count, amp rating, and coil voltage against your old part.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photo all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contacts pull in on a cooling call and drop out when satisfied.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Chattering or buzzing contactor
  • Compressor runs after thermostat is satisfied
  • Unit fails to start despite a 24V call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS048S0XA0AAAA — 24V Coil 30 Amp | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS048S0XA0AAAA — 24V Coil 30 Amp | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS048S0XA0AAAA — 24V Coil 30 Amp | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online