Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RHS048S0BA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RHS048S0BA0AAAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM definite-purpose contactor (P/N 1178074) is the primary line-voltage switch for the ICP Tempstar Heil RHS048S0BA0AAAA. When the thermostat calls, a 24V signal energizes the coil and pulls two 30A poles closed, sending power to the compressor and condenser fan motor. Because they cycle constantly, contactors are one of the most common failure points in a condensing unit — contacts pit and burn until the unit won't start, or weld shut so the compressor never turns off. A buzzing or chattering coil is an early warning.

Specifications

Spec Value
Part Number 1178074
Type Definite-Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2 (Double-Pole)
Contact Rating 30A
Coil Voltage 24V

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil RHS048S0BA0AAAA heat pump and other RHS048-series condensing units using a 2-pole 30A, 24V-coil contactor. Verify your model and part number before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or label each, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each lead per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor/fan energize.

Signs You Need a Replacement

  • Unit won't start or only the fan runs
  • Loud buzzing or chattering at the contactor
  • Pitted, burned, or melted contacts
  • Compressor won't shut off (contacts welded closed)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS048S0BA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS048S0BA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS048S0BA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online