Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RHS036L0CB0AAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RHS036L0CB0AAA — 24V Coil | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine ICP 2-pole definite-purpose contactor (OEM part 1178074) is the electromechanical switch that powers your outdoor condensing unit. Rated at 30 amps with a 24-volt control coil, it takes the low-voltage signal from the thermostat or control board and closes its contacts to deliver line voltage to the compressor and condenser fan motor. A failed contactor leaves the unit unable to start, or — when the contacts weld together — running without stopping. Burned, pitted, or chattering contacts are the single most frequent cause of a no-cooling complaint on this equipment.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP (Heil / Tempstar)
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V

Compatibility

Direct OEM replacement for ICP/Heil/Tempstar/Comfortmaker model RHS036L0CB0AAA and related condensing units and heat pumps using a 2-pole, 30A, 24V-coil contactor. Verify coil voltage and amp rating against the contactor you are replacing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage at the terminals with a multimeter.
  2. Access — Remove the condensing unit service panel.
  3. Document — Photograph all wire connections before disconnecting.
  4. Remove — Disconnect line, load, and 24V coil leads, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly as photographed.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in cleanly without chatter.

Signs You Need a Replacement

  • Outdoor unit won't start on a cooling call.
  • Buzzing, humming, or chattering from the contactor.
  • Visible pitting, burning, or melted housing on the contacts.
  • Compressor runs continuously because the contacts welded shut.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS036L0CB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS036L0CB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS036L0CB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.