This OEM 2-pole, 30-amp contactor (PN 1178074) is the genuine replacement for the ICP Tempstar Heil RHH090L0BA0AAAA heat pump. The contactor is an electrically operated switch with a 24V coil that energizes the compressor and condenser fan when the thermostat calls for cooling or heat-pump operation. Over time the contact points pit, weld, or burn — causing the unit to fail to start, run continuously, or hum without engaging. Replacing a worn contactor is one of the most common and inexpensive HVAC repairs.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole
Rating 30 Amp
Coil Voltage 24V
Application Compressor / Condenser Fan

Compatibility

Built for the ICP / Tempstar / Heil RHH090L0BA0AAAA heat pump and other Comfortmaker, Heil, and Tempstar condensing units using a 2-pole 30A 24V definite-purpose contactor. Confirm the OEM part number and physical footprint before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit's service panel.
  3. Document — Photograph every wire on the line, load, and coil terminals before disconnecting.
  4. Remove — Move wires one at a time to the new contactor, then unbolt the old unit from the bracket.
  5. Install — Mount the new contactor and reconnect all leads exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor/fan start on a cooling call.

Signs You Need a Replacement

  • Compressor and fan won't start despite a cooling call
  • Loud humming or buzzing from the contactor
  • Pitted, burned, or welded contact points
  • Unit runs nonstop because contacts are stuck closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHH090L0BA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHH090L0BA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHH090L0BA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online