Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RHH060L0XA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RHH060L0XA0AAAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole definite purpose contactor (part number 1178074) for the ICP/Tempstar/Heil RHH060L0XA0AAAA heat pump. The contactor is the electromagnetic switch that energizes the compressor and condenser fan motor whenever the thermostat calls for cooling or heating. A 24-volt control signal pulls in the coil, closing the contacts and passing line voltage to the outdoor unit. Rated at 30 amps per pole with a 24-volt coil, it matches the compressor and fan load on this system. Common failure symptoms include a humming or chattering outdoor unit, pitted or welded contacts that keep the compressor running, or a unit that will not start because the coil has burned open.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor, 2-Pole
Brand ICP / Tempstar / Heil
Current Rating 30 Amps
Coil Voltage 24 VAC
Poles 2

Compatibility

Engineered for the ICP/Tempstar/Heil RHH060L0XA0AAAA and shared across many ICP-family condensing units and heat pumps that use a 2-pole 30A 24V contactor. Confirm the existing part number and coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser unit's electrical access panel.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Move the line, load, and 24V coil wires to the new contactor one terminal at a time, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect every wire per your photo.
  6. Test — Restore power and confirm the contacts pull in and the compressor and fan start on a cooling call.

Signs You Need a Replacement

  • Loud buzzing or humming from the outdoor unit
  • Burned, pitted, or welded contacts
  • Compressor runs continuously and will not shut off
  • Outdoor unit completely dead on a cooling call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHH060L0XA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHH060L0XA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHH060L0XA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online