Overview

This genuine OEM 2-pole, 30-amp contactor (part number 1178074, CONTACTOR 2P 30A 24V) is the main switching relay for the ICP / Tempstar / Heil RHH048S0XA0AAAA 4-ton heat pump. Its 24V coil is energized by the thermostat through the control board; when it pulls in, the contactor closes its 30A line-voltage contacts to power the compressor and condenser fan motor. Contactors are a common failure point — pitted or welded contacts, a chattering or burned-out coil, and insect or debris fouling all prevent the outdoor unit from starting or cause it to stick on. Replacing a worn contactor restores clean, reliable switching and protects the compressor from voltage drop and arcing.

Specifications

Spec Value
Part Number 1178074
Type Definite-Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amp
Coil Voltage 24 Volt
Brand ICP (Tempstar / Heil)
Fitment OEM

Compatibility

Designed for the RHH048S0XA0AAAA heat pump and other ICP-family Tempstar, Heil, and Comfortmaker condensing units that use a 2-pole 30A definite-purpose contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage match your original.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter across the contactor line terminals.
  2. Access — Remove the condensing unit service panel to reach the control box.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Move wires one at a time to the new contactor, or label them, then unscrew and lift out the old contactor.
  5. Install — Mount the new 30A contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but won't start
  • Pitted, burned, or welded contacts
  • Compressor runs continuously and won't shut off
  • Chattering contactor or dead 24V coil

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHH048S0XA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHH048S0XA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHH048S0XA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online