This genuine OEM 2-pole definite purpose contactor (part number 1178074) is the main switching relay for the ICP/Heil/Tempstar RHH048L0XA0AAAA heat pump condensing unit. Rated at 30 amps per pole with a 24-volt control coil, it energizes the compressor and condenser fan whenever the thermostat calls for heating or cooling. Contactors are a leading failure point in outdoor units: the silver contacts pit and burn from repeated switching, and the coil can open from heat and age. Watch for a unit that hums but won't start, a chattering or buzzing contactor, contacts that weld closed and keep the compressor running, or no 24V pull-in at all.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP (Heil / Tempstar)
Poles 2-Pole
Rating 30 Amps
Coil Voltage 24V
Fits Model RHH048L0XA0AAAA

Compatibility

Direct OEM replacement for the ICP/Heil/Tempstar RHH048L0XA0AAAA heat pump. The 2-pole, 30A, 24V configuration is also a common service replacement across many 2–4 ton residential outdoor units on the same platform. Confirm pole count, amp rating, and coil voltage against the part you remove.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter at the contactor line terminals.
  2. Access — Remove the condenser unit's electrical service panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and coil leads, then unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor, transfer each wire to the matching terminal per your photo, and torque connections snug.
  6. Test — Restore power, call for operation, and confirm the contactor pulls in cleanly and the compressor and fan energize.

Signs You Need a Replacement

  • Loud buzzing, humming, or chattering from the outdoor unit
  • Compressor won't start even though the thermostat is calling
  • Pitted, blackened, or welded contacts visible on inspection
  • Unit runs continuously and won't shut off (stuck contacts)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHH048L0XA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHH048L0XA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHH048L0XA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online