This OEM contactor (part #1178074) is the genuine 2-pole, 30-amp, 24-volt-coil contactor for the ICP/Tempstar/Heil RHH036H0BA0AAAA heat pump. The contactor is the high-current switch that powers the compressor and condenser fan motor whenever the thermostat calls for cooling. A 24V signal energizes the coil, pulling the contacts closed to pass line voltage to the outdoor unit. Over time the contacts pit, burn, and stick — or the coil weakens — causing the unit to chatter, fail to start, or run continuously even after the call ends. Replacing a worn contactor is a routine, high-value repair that prevents compressor damage.

Specifications

Spec Value
Part Number 1178074
Description Contactor, 2-Pole, 30A, 24V
Type Definite Purpose Contactor
Poles 2
Contact Rating 30 Amps
Coil Voltage 24 VAC
Brand ICP / Tempstar / Heil
Fit OEM Direct Replacement

Compatibility

Engineered as the factory replacement for the ICP RHH036H0BA0AAAA heat pump and shared-platform Tempstar, Heil, and Comfortmaker condensing units that used part 1178074. Verify pole count, amp rating, and 24V coil against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each lead per your photo.
  6. Test — Restore power and confirm the contacts pull in on a cooling call and the unit starts cleanly.

Signs You Need a Replacement

  • Loud chattering or buzzing from the outdoor unit
  • Compressor and fan won't start on a cooling call
  • Pitted, burned, or welded-shut contacts
  • Unit keeps running after the thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHH036H0BA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHH036H0BA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHH036H0BA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online