This is a genuine OEM 2-pole, 30-amp contactor with a 24-volt coil, part number 1171554, for ICP, Tempstar, and Heil equipment. A contactor is an electrically operated switch: when the 24V coil energizes on a call from the control board, an electromagnet pulls the contacts closed and passes line voltage to the load it controls. Over time the contacts arc, pit, and corrode, and the coil can weaken or burn out. Symptoms of a failing contactor include a system that will not energize, chattering or buzzing at the contactor, contacts that stick closed so the load never shuts off, or visible burning and melting on the contact points. Replacing it with the correct OEM 30A 24V unit restores clean, reliable switching and prevents nuisance no-cool or no-start calls.

Specifications

Spec Value
Part Number 1171554
Type Contactor, 2 Pole
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2
Brand ICP / Tempstar / Heil OEM
Fitment OEM Replacement

Compatibility

Specified as the factory replacement contactor for the ICP Tempstar Heil RGS303SSAA0AAAA. This 2-pole 30A 24V configuration is common across ICP-built furnace and condensing-unit platforms; verify the pole count, amp rating, and coil voltage match your existing part.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time or label them, unbolt the old contactor from its bracket, and remove it.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, initiate a call, and confirm the contactor pulls in cleanly and the load energizes.

Signs You Need a Replacement

  • System will not start on a valid 24V call
  • Loud chattering or buzzing at the contactor
  • Contacts stick closed and the load runs nonstop
  • Burnt, pitted, or melted contact points

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS303SSAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS303SSAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS303SSAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.