This is a genuine OEM 2-pole 30-amp contactor (part number 1171554) for the ICP / Tempstar / Heil RGS303SREA0AAAA system. A contactor is an electrically controlled switch that uses a 24V signal from the thermostat circuit to energize its coil, which pulls the contacts closed and sends line voltage to the compressor and condenser fan motor. Over time the contact points pit, burn, and weld from the inrush current of every cooling cycle. A failing contactor causes hard starts, chattering, intermittent cooling, or a unit that won't shut off because the contacts have welded closed. Replacing it with the correct 2-pole 30A 24V OEM contactor restores clean, reliable switching and protects the compressor from voltage drop and arcing damage.

Specifications

Spec Value
OEM Part Number 1171554
Type Contactor, 2-Pole
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2
Fit OEM Direct Replacement

Compatibility

Designed as a direct-fit replacement for the ICP / Tempstar / Heil RGS303SREA0AAAA and related ICP-family equipment specifying OEM part 1171554. Verify the rating and part number on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to reach the contactor.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and coil wires, then unscrew the old contactor.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a call for cooling.

Signs You Need a Replacement

  • Chattering or buzzing when the unit calls for cooling
  • Compressor and fan won't start, or start intermittently
  • System won't shut off (welded contacts)
  • Visible pitting, burning, or melted housing on the contactor

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS303SREA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS303SREA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS303SREA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.