Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS303SRAA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS303SRAA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole, 30-amp contactor with a 24V coil (part number 1171554) for the ICP Tempstar Heil RGS303SRAA0AAAA system. The contactor is an electrically operated switch: when the 24V control circuit energizes the coil, the contacts close and pass line voltage to the connected load. Over time the contacts pit, burn, and weld from arcing, while the coil can fail open. Symptoms include a unit that will not energize on a call, chattering or humming at the contactor, or a system that stays running because the contacts have welded shut. Replacing a worn contactor restores reliable, safe switching.

Specifications

Spec Value
Part Number 1171554
Type Contactor
Brand ICP / Tempstar / Heil
Contact Rating 30A
Coil Voltage 24V
Poles 2-Pole
Fitment OEM Replacement

Compatibility

Built for the ICP family RGS303SRAA0AAAA and shared across compatible Tempstar, Heil, Comfortmaker, Arcoaire, and KeepRite models using a 2-pole 30A 24V contactor. Verify pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Disconnect the wiring, unscrew the old contactor from its mount, and lift it out.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for operation, and confirm the contacts pull in cleanly with no chatter.

Signs You Need a Replacement

  • Burned, pitted, or welded contacts
  • Chattering or buzzing at the contactor
  • System will not energize on a call
  • Unit runs continuously and will not shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS303SRAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS303SRAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS303SRAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online