Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS303SFFA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS303SFFA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole, 30-amp contactor with a 24-volt coil (ICP part number 1171554) for the ICP/Tempstar/Heil RGS303SFFA0AAAA. The contactor is the electrical switch that makes and breaks line voltage to the compressor and condenser fan motor on every call for cooling. Its 24V coil is energized by the low-voltage control circuit, pulling the contacts closed to deliver power. Over thousands of cycles the contacts pit, burn, and weld, leading to no-cool calls or a system that won't shut off. A fresh contactor restores reliable switching and protects downstream components.

Specifications

Spec Value
Part Number 1171554
Type Contactor, 2-Pole
Brand ICP / Tempstar / Heil
Contact Rating 30A
Coil Voltage 24V
Poles 2
Fitment OEM

Compatibility

A direct-fit replacement for the ICP/Tempstar/Heil RGS303SFFA0AAAA. ICP, Tempstar, Heil, and Comfortmaker share equipment platforms, so this 2-pole 30A contactor also services many sibling RGS-series units. Confirm your existing contactor is a 2-pole 30A device with a 24V coil and carries part number 1171554 before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter at the contactor line terminals.
  2. Access — Remove the service panel to expose the contactor.
  3. Document — Photograph all line, load, and 24V coil connections before removing any wires.
  4. Remove — Transfer wires one at a time, or pull all leads after labeling, then unscrew the old contactor from its base.
  5. Install — Mount the new 2-pole 30A contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and the compressor and fan energize.

Signs You Need a Replacement

  • No cooling even though the thermostat is calling and the coil is getting 24V
  • Buzzing or chattering at the contactor instead of a solid pull-in
  • Pitted, burnt, or welded contacts that won't open
  • System that continues running after the thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS303SFFA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS303SFFA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS303SFFA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online