Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS303LRAA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS303LRAA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 2-pole definite purpose contactor (part number 1171554) is the switching component for the ICP/Tempstar/Heil RGS303LRAA0AAAA system. Rated at 30 amps with a 24-volt coil, the contactor closes its contacts when the thermostat calls for cooling, passing line voltage to the compressor and condenser fan motor. Constant make-and-break cycling pits and erodes the contact points over time, and a worn contactor is a leading cause of a unit that hums without starting, chatters, or refuses to shut off when the contacts weld closed. Installing a fresh OEM contactor restores clean switching and protects the costlier motor and compressor on the load side.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole
Rating 30 Amp
Coil Voltage 24V
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP RGS303LRAA0AAAA and other compatible Tempstar, Heil, and Comfortmaker equipment using the 1171554 contactor. Confirm the part number on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and pull the disconnect; verify zero voltage with a multimeter before touching any terminals.
  2. Access — Remove the service panel to expose the electrical compartment.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Label and remove the line, load, and 24V coil wires, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, place a cooling call, and confirm the contactor pulls in cleanly and the unit starts.

Signs You Need a Replacement

  • Unit hums or buzzes but the compressor and fan won't start.
  • Visible pitting, burning, or melted plastic on the contact points.
  • Chattering or rapid clicking on a cooling call.
  • System won't shut off because the contacts have welded closed.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS303LRAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS303LRAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS303LRAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online