Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS303HREA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS303HREA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole 30A contactor (part number 1171554) is the switching relay that energizes the high-voltage load on the ICP / Tempstar / Heil RGS303HREA0AAAA system. When the 24V coil is energized by the control circuit, the contactor closes its 30-amp poles to deliver line power. A larger 3-pole 60A contactor (1183142) is available for higher-load configurations. Contactor failure shows up as pitted or welded contacts, a chattering coil, or no power passing through when the system calls — leaving the unit unable to run. Pitting from arcing is a normal wear pattern that makes contactors a routine maintenance replacement.

Specifications

Spec Value
Part Number 1171554 (2P 30A), 1183142 (3P 60A)
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole (3-Pole option)
Contact Rating 30 Amp (60 Amp option)
Coil Voltage 24V
Application Condenser / Compressor Switching

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS303HREA0AAAA and parts-compatible units using a 2-pole 30A 24V-coil contactor. For higher-amperage applications, select the 3-pole 60A version (1183142). Confirm pole count, amp rating, and 24V coil before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical-compartment service panel.
  3. Document — Photograph the line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unscrew and remove the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for operation, and confirm the contactor pulls in cleanly and passes voltage.

Signs You Need a Replacement

  • Burned, pitted, or welded contact points.
  • Buzzing or chattering coil that won't pull in fully.
  • System won't start despite a valid 24V call.
  • No line voltage passing through the closed contacts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS303HREA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS303HREA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS303HREA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR