Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS300STFA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS300STFA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole, 30-amp contactor (part 1171554) with a 24V coil for the ICP / Tempstar / Heil RGS300STFA0AAAA system. A contactor is the electrically operated switch that powers the high-current load: when the 24V control signal energizes the coil, the contacts pull in and pass line voltage to the load; when the call ends, the contacts open. Over thousands of cycles the contacts pit, burn, and arc, and the coil can weaken or fail. Symptoms of a failing contactor include the load not energizing, loud buzzing or humming, chattering contacts, contacts welded closed so the unit never shuts off, and visible burning or pitting on the contact faces.

Specifications

Spec Value
OEM Part Number 1171554
Type 2-Pole contactor
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2
Fit OEM direct replacement

Compatibility

Direct-fit OEM replacement for the ICP / Tempstar / Heil RGS300STFA0AAAA and other RGS-series units calling for a 2-pole 30A 24V-coil contactor (part 1171554). Verify pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control compartment service panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer wires one at a time, then unscrew the old contactor from its mount.
  5. Install — Mount the new 2-pole 30A contactor and reconnect each wire exactly per your photo, confirming the 24V coil terminals.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a call and drops out when satisfied.

Signs You Need a Replacement

  • Loud buzzing, humming, or chattering from the contactor.
  • Load fails to energize on a valid 24V call.
  • Burned, pitted, or melted contacts.
  • Contacts welded closed — the unit will not shut off.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS300STFA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS300STFA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS300STFA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online