Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS300SFBB0AGAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS300SFBB0AGAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 2-pole, 30-amp definite-purpose contactor (part number 1171554) with a 24V coil for the ICP / Tempstar / Heil RGS300SFBB0AGAA system. The contactor is the heavy-duty switch that the 24V control circuit energizes to send line voltage to the compressor and condenser fan. As contacts age they pit, burn, and weld — causing the unit to fail to start, chatter, or remain energized after the thermostat is satisfied. A new OEM-spec contactor restores clean, reliable switching and protects the more expensive components downstream.

Specifications

Spec Value
OEM Part Number 1171554
Type Definite-Purpose Contactor
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fitment OEM Replacement

Compatibility

Direct-fit replacement for the ICP Tempstar Heil RGS300SFBB0AGAA and related ICP-family units specifying the 1171554 contactor. Confirm pole count, 30A rating, and 24V coil against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter at the contactor terminals.
  2. Access — Remove the service panel to expose the contactor.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unfasten and remove the old contactor.
  5. Install — Mount the new contactor in the same orientation and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and drops out when satisfied.

Signs You Need a Replacement

  • Compressor or condenser fan will not start on a cooling call.
  • Loud buzzing, chattering, or humming from the contactor.
  • Unit keeps running after the thermostat is satisfied (welded contacts).
  • Visibly pitted, burned, or corroded contact points.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS300SFBB0AGAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS300SFBB0AGAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS300SFBB0AGAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online