This genuine OEM 2-pole, 30-amp definite-purpose contactor (part #1171554) with a 24V coil is the switching contactor for the ICP / Tempstar / Heil RGS300SDAA0AAAA system. A contactor is an electrically operated switch: when the 24VAC control signal energizes the coil, the contactor pulls in and its two 30A power poles close to deliver line voltage to the load. Over thousands of cycles the contacts pit, burn, or weld, and the coil can fail open. Symptoms include a unit that won't energize on a call, a contactor that buzzes loudly, or contacts that stick closed and leave the load running continuously. This OEM contactor matches the factory coil voltage, contact rating, and pole count for a direct, reliable replacement.

Specifications

Spec Value
Part Number 1171554
Type Definite-Purpose Contactor
Brand ICP / Tempstar / Heil
Contact Rating 30 A
Coil Voltage 24 VAC
Poles 2 (Double-Pole)
Fitment OEM

Compatibility

Built for the ICP/Tempstar/Heil RGS300SDAA0AAAA and shared-platform models that use a 2-pole 30A 24V contactor. Confirm coil voltage and amp rating against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service/control panel.
  3. Document — Photograph all line, load, and coil connections before disconnecting.
  4. Remove — Detach the wires and unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each terminal exactly per your photo.
  6. Test — Restore power and verify the contactor pulls in cleanly on a call and contacts close fully.

Signs You Need a Replacement

  • System won't energize when there's a call for operation
  • Loud buzzing or humming from the contactor
  • Contacts stuck closed so the load runs continuously
  • Pitted, burned, or welded contacts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS300SDAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS300SDAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS300SDAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.