The OEM 2-Pole 30A Contactor (part #1171554) is the genuine ICP / Heil / Tempstar switching relay used on the RGS300LFEA0AAAA system. With a 24-volt coil and two 30-amp poles, it energizes the line-voltage load when the thermostat or control board calls for operation. Contactors wear out from arcing, pitting, and coil failure — symptoms include chattering, welded contacts that won't drop out, a buzzing coil, or a unit that won't start at all. Replacing it with the OEM part restores clean, reliable switching and protects downstream components from voltage drop and overheating.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP (Heil / Tempstar)
Fits Model RGS300LFEA0AAAA

Compatibility

Direct OEM replacement for the RGS300LFEA0AAAA and other ICP-family systems sold under Heil, Tempstar, and Comfortmaker that use a 2-pole 30A definite-purpose contactor with a 24V coil. Verify pole count, amp rating, and coil voltage against your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control access panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time or unfasten the contactor bracket and lift out the old unit.
  5. Install — Mount the new contactor, reconnect each wire to the matching terminal per your photos.
  6. Test — Restore power, call for operation, and confirm the contactor pulls in cleanly and the load energizes.

Signs You Need a Replacement

  • Chattering or buzzing when energized
  • Pitted, blackened, or welded contacts
  • Unit won't start or won't shut off
  • Coil tests open or out of spec

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS300LFEA0AAAA — 24V Coil OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS300LFEA0AAAA — 24V Coil OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS300LFEA0AAAA — 24V Coil OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online