Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS243SSFA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS243SSFA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite purpose contactor (Part No. 1171554) is the electromechanical switch that energizes the high-voltage load circuit in your ICP RGS243SSFA0AAAA system. It is rated for 30 amps with a 24-volt control coil. When the thermostat or control board calls for operation, the 24V coil pulls in the contactor, closing both poles and delivering line voltage to the load. Worn, pitted, or chattering contactors are one of the most common causes of intermittent or failed operation. Symptoms of failure include a buzzing or humming relay, contacts that weld shut leaving equipment running continuously, or burnt, melted terminals that prevent the circuit from closing at all.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Brand ICP
Poles 2-Pole
Current Rating 30A
Coil Voltage 24V
Fit OEM Replacement

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS243SSFA0AAAA. Also a common service part across many ICP-family units using a 2-pole 30A, 24V-coil contactor. Always confirm the original part number and coil voltage before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter before touching any terminal.
  2. Access — Remove the service/control panel to expose the contactor.
  3. Document — Photograph all wire positions before disconnecting anything.
  4. Remove — Disconnect line, load, and 24V coil leads, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly with no chatter on a call for operation.

Signs You Need a Replacement

  • Loud buzzing or humming from the relay
  • Pitted, burnt, or welded contacts
  • Equipment runs continuously or won't start on demand
  • Visible melting or discoloration at the terminals

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS243SSFA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS243SSFA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS243SSFA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online