This OEM ICP definite-purpose contactor (part number 1171554) is a 2-pole, 30-amp magnetic switch with a 24-volt coil used to energize the compressor and condenser fan in your ICP Tempstar/Heil RGS243SSAA0AAAA system. When the thermostat calls for cooling, the 24V coil pulls the contacts closed and sends line voltage to the compressor and fan motor. Over time the contact points pit, burn, and weld from arcing, while ants or debris can jam the plunger. Symptoms of a failing contactor include a system that won't start, a chattering or buzzing contactor, contacts that stick closed so the unit won't shut off, and visible burning or pitting on the contact terminals.
| Spec | Value |
|---|---|
| Part Number | 1171554 |
| Description | Contactor 2P 30A 24V |
| Type | 2-Pole Definite Purpose Contactor |
| Amperage | 30 Amps |
| Coil Voltage | 24V |
| Poles | 2 |
| Brand | ICP (Tempstar / Heil) |
| Fits Model | RGS243SSAA0AAAA |
| Fit | OEM Direct Replacement |
Direct OEM replacement for the ICP Tempstar Heil RGS243SSAA0AAAA and other ICP-family units using contactor 1171554. The 2-pole, 30A, 24V-coil configuration is a common definite-purpose size — confirm the amp rating, pole count, and coil voltage match your original before installing.