This OEM definite-purpose contactor (part #1171554) is a 2-pole, 30-amp switch with a 24V control coil used in your ICP / Tempstar / Heil RGS243SFAA0AAAA system. The contactor acts as the high-voltage relay that energizes the load when the 24V control circuit calls. A 24V signal pulls in the magnetic coil, closing the contacts to pass line voltage to the motor or compressor circuit. Over time the contacts pit, arc, and weld, or the coil burns out — leading to a unit that won't start, chatters, or won't shut off. Worn contacts also cause hard starts and nuisance tripping. Replacing the contactor restores clean, reliable switching and protects downstream components.

Specifications

Spec Value
Part Number 1171554
Type Definite-Purpose Contactor
Poles 2
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fitment OEM Direct Replacement

Compatibility

Direct OEM-fit replacement for the ICP / Tempstar / Heil RGS243SFAA0AAAA and related Comfortmaker / Heil equipment using a 2-pole 30A 24V-coil contactor. Verify pole count, amp rating, and coil voltage against your existing part before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control panel cover.
  3. Document — Photograph all line, load, and 24V coil wire positions before disconnecting.
  4. Remove — Transfer wires one at a time, then unscrew and remove the old contactor.
  5. Install — Mount the new 2-pole 30A contactor and land each wire on the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a call and drops out when satisfied.

Signs You Need a Replacement

  • Unit won't start or fails to energize on a call
  • Buzzing, chattering, or humming from the contactor
  • Pitted, burned, or welded contacts
  • System won't shut off (contacts stuck closed)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS243SFAA0AAAA — OEM 24V Coil 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS243SFAA0AAAA — OEM 24V Coil 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS243SFAA0AAAA — OEM 24V Coil 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online