Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS243SDEA0AAAA — 24V Coil OEM 1171554 | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS243SDEA0AAAA — 24V Coil OEM 1171554 | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM definite-purpose contactor, ICP part number 1171554, is a 2-pole, 30-amp unit with a 24-volt coil used to switch line power to the compressor and condenser fan on equipment paired with your ICP/Heil/Tempstar RGS243SDEA0AAAA system. The 24V coil energizes from the control circuit and pulls the contacts closed to start the load. Pitted, welded, or chattering contacts and a burned-out coil are the most common failures, leading to a system that won't start or won't shut off.

Specifications

Spec Value
Part Number 1171554 (CONTACTOR 2P 30A 24V)
Type Definite Purpose Contactor, 2-Pole
Brand ICP / Heil / Tempstar
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Fit OEM Direct Replacement

Compatibility

Direct OEM fit for systems served by the ICP Tempstar Heil RGS243SDEA0AAAA and related units originally using contactor 1171554. Confirm pole count, contact amperage, and 24V coil voltage match your old part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control access panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Disconnect the wires, remove the mounting screws, and lift out the old contactor.
  5. Install — Mount the new 1171554 contactor and reconnect each wire exactly per your photos.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan energize.

Signs You Need a Replacement

  • System won't start even though the thermostat is calling
  • Loud buzzing, chattering, or humming at the contactor
  • Pitted, burned, or welded contacts that stick closed
  • Compressor or fan runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS243SDEA0AAAA — 24V Coil OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS243SDEA0AAAA — 24V Coil OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS243SDEA0AAAA — 24V Coil OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online