Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS243LDAA0AAAA — 24V Coil 30 Amp | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS243LDAA0AAAA — 24V Coil 30 Amp | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM definite-purpose contactor (part number 1171554) is a 2-pole, 30 amp unit with a 24-volt coil for the ICP/Heil/Tempstar RGS243LDAA0AAAA system. The contactor uses the 24V control signal to energize the line-voltage load, switching power to the compressor and/or condenser fan on each call. Pitted or welded contacts, a chattering or open coil, and insect/debris fouling all cause failure to start, intermittent operation, or contacts that stick closed. Replacing a worn contactor restores clean, reliable switching and protects downstream components.

Specifications

Spec Value
Part Number 1171554
Description Contactor 2P 30A 24V
Type 2-Pole Definite Purpose
Rating 30 Amps
Coil Voltage 24V
Poles 2
Brand ICP (Heil / Tempstar / Comfortmaker)
Fits Model RGS243LDAA0AAAA
Fit OEM Replacement

Compatibility

Engineered for the ICP RGS243LDAA0AAAA and matching Heil, Tempstar, and Comfortmaker equipment using a 2-pole 30A / 24V coil contactor. Verify pole count, amp rating, and coil voltage against the old part before ordering.

Installation Guide

  1. Safety First — Disconnect line and control power; verify zero voltage with a multimeter.
  2. Access — Remove the electrical/service panel.
  3. Document — Photograph all line, load, and coil (24V) wiring before disconnecting.
  4. Remove — Transfer wires one at a time, or label each, then unbolt the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect every lead exactly as photographed.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a call with no chatter and proper voltage across the contacts.

Signs You Need a Replacement

  • System won't start or starts intermittently
  • Buzzing or chattering at the contactor
  • Pitted, burned, or welded-closed contacts
  • Unit keeps running because contacts won't release

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS243LDAA0AAAA — 24V Coil 30 Amp | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS243LDAA0AAAA — 24V Coil 30 Amp | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS243LDAA0AAAA — 24V Coil 30 Amp | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online