Overview

This OEM definite-purpose contactor switches line voltage to the compressor and condenser fan in the ICP RGS243HREA0AAAA. The 24V coil pulls in the contacts whenever the thermostat calls for cooling, sending power to the outdoor unit. This listing covers the 2-pole 30A contactor (OEM 1171554); the RGS243 platform also uses the 3-pole 40A (1172449) and 3-pole 60A (1183142) variants depending on configuration. Contactors fail from arcing, pitted or welded contacts, and worn coils — symptoms include a chattering buzz, an outdoor unit that won't energize, or a unit that won't shut off because the contacts are stuck closed. A fresh OEM contactor restores clean, reliable switching and protects downstream components.

Specifications

Spec Value
OEM Part Numbers 1171554 (2P 30A), 1172449 (3P 40A), 1183142 (3P 60A)
Type Definite-Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Fit OEM Direct Replacement

Compatibility

Direct-fit OEM replacement for the ICP/Tempstar/Heil RGS243HREA0AAAA and related RGS243 series units. Confirm pole count and amperage against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove — Transfer wires one at a time, then unbolt the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each lead per your photo.
  6. Test — Restore power and confirm the contacts pull in on a call for cooling.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Loud buzzing or chattering from the contactor
  • Outdoor unit won't start, or won't shut off
  • Weak or open 24V coil that won't pull in

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS243HREA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS243HREA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS243HREA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online