This OEM 2-pole, 30-amp contactor (part number 1171554) with a 24V coil fits the ICP / Tempstar / Heil RGS240STFA0AAAA system. The contactor is an electrically operated switch that closes its high-current contacts when the 24V control circuit energizes the coil, sending line voltage to the compressor and condenser fan motor. Because it cycles thousands of times per season, the contacts pit, burn, and eventually weld or fail to close. Common symptoms include a unit that will not start, contacts that buzz or chatter, a contactor that stays pulled in after the call ends, or visible arcing and pitting on the contact faces. A fresh contactor restores reliable, full-voltage switching to your outdoor equipment.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fits Model RGS240STFA0AAAA
Fit Type OEM Replacement

Compatibility

Built for the ICP / Tempstar / Heil RGS240STFA0AAAA and other units that use a 2-pole 30A definite-purpose contactor with a 24V coil. Match the amp rating, pole count, and coil voltage to your existing contactor before ordering.

Installation Guide

  1. Safety First – Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access – Remove the unit's electrical-compartment service panel.
  3. Document – Photograph every line, load, and coil wire before disconnecting.
  4. Remove – Disconnect the leads, unscrew the contactor from its bracket, and remove it.
  5. Install – Mount the new contactor and reconnect line, load, and 24V coil leads per your photo.
  6. Test – Restore power, call for cooling, and confirm the contactor pulls in and the compressor and fan energize.

Signs You Need a Replacement

  • Outdoor unit will not start on a cooling call.
  • Loud buzzing or chattering from the contactor.
  • Contacts remain closed after the call for cooling ends.
  • Visible pitting, arcing, or melted contact faces.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240STFA0AAAA – 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240STFA0AAAA – 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240STFA0AAAA – 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.