Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS240SREA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS240SREA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine ICP OEM contactor (part number 1171554) is a 2-pole, 30-amp device with a 24-volt coil for the RGS240SREA0AAAA. The contactor is the high-voltage switch that powers the compressor and condenser fan motor. When the thermostat calls for cooling, the 24V control signal energizes the coil, pulling the contacts closed and sending line voltage to the outdoor unit. Over thousands of cycles the contacts pit, burn, or weld, and the coil can fail — leaving the system unable to start or unable to shut off. A fresh OEM contactor restores clean, reliable switching and protects downstream motors.

Specifications

Spec Value
Part Number 1171554
Description Contactor, 2-Pole
Poles 2
Rating 30 Amps
Coil Voltage 24V
Brand ICP (Tempstar / Heil / Comfortmaker)
Fitment OEM Direct Replacement
Fits Model RGS240SREA0AAAA

Compatibility

Direct OEM replacement for the ICP RGS240SREA0AAAA and equivalent Tempstar, Heil, and Comfortmaker units using a 2-pole 30A 24V-coil contactor. Verify pole count, amp rating, and coil voltage against your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and outdoor disconnect, then confirm zero voltage with a multimeter.
  2. Access — Remove the service panel on the condensing unit.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unbolt the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the unit energizes.

Signs You Need a Replacement

  • Buzzing or chattering at the contactor
  • Pitted, burned, or welded contacts
  • Compressor won't start or won't shut off
  • Coil fails to pull the contacts closed on a cooling call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240SREA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240SREA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240SREA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online