Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS240SFEA0AAAA — 24V Coil OEM 1171554 | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS240SFEA0AAAA — 24V Coil OEM 1171554 | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This ICP 2-pole 30-amp contactor with a 24-volt coil (OEM part #1171554) is the electromagnetic switch that energizes the compressor and condenser fan on your ICP/Heil/Tempstar RGS240SFEA0AAAA system. When the thermostat calls for cooling, the 24V coil pulls the contacts closed to pass line voltage to the load. Pitted, burned, or chattering contacts cause hard starts, buzzing, or a system that won't run at all. Replacing a worn contactor restores clean, reliable switching and prevents arcing damage to downstream components.

Specifications

Spec Value
Part Number 1171554
Description Contactor, 2-Pole, 30A, 24V Coil
Type 2-Pole Definite Purpose Contactor
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Brand ICP (Heil / Tempstar / Comfortmaker)
Fits Model RGS240SFEA0AAAA
Fitment OEM Direct Replacement

Compatibility

This 2-pole 30A 24V contactor is a direct OEM fit for the ICP/Heil/Tempstar RGS240SFEA0AAAA and other models specifying part 1171554. Verify pole count, amp rating, and 24V coil voltage against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker. Verify zero voltage with a multimeter at the contactor terminals.
  2. Access — Remove the unit electrical access/service panel.
  3. Document — Photograph all line, load, and 24V coil wire positions before disconnecting.
  4. Remove — Label and disconnect the wires, unscrew the mounting, and lift out the old contactor.
  5. Install — Mount the new 2-pole contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the coil pulls in on a cooling call and the contacts close without chatter.

Signs You Need a Replacement

  • Loud buzzing or chattering at the contactor
  • Pitted, burned, or welded contacts
  • Compressor/fan won't start or won't shut off
  • Coil fails to pull the contacts closed on a 24V call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240SFEA0AAAA — 24V Coil OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240SFEA0AAAA — 24V Coil OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240SFEA0AAAA — 24V Coil OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online