Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS240SDFA0AAAA — 24V Coil OEM 1171554 | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS240SDFA0AAAA — 24V Coil OEM 1171554 | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM definite-purpose contactor for the ICP/Heil/Tempstar RGS240SDFA0AAAA system, OEM part number 1171554. It is a 2-pole unit rated 30 amps with a 24-volt control coil. The contactor is the high-voltage switch that energizes the compressor and condenser fan when the thermostat calls for cooling. Over time the contacts pit and burn, or the coil weakens, causing chattering, welded contacts that keep the unit running, or a system that won't start at all.

Specifications

Spec Value
Part Number 1171554
Type Definite-Purpose Contactor, 2-Pole
Brand ICP / Heil / Tempstar
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Fit OEM

Compatibility

A direct OEM fit for the ICP/Heil/Tempstar RGS240SDFA0AAAA unit and other models specifying contactor 1171554. Confirm pole count, contact amperage, and 24V coil against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control/electrical access panel.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, then unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Loud chattering or buzzing when the system engages
  • Pitted, burned, or welded contacts
  • Compressor won't start, or won't shut off (stuck closed)
  • Coil reads open or out of spec on a multimeter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240SDFA0AAAA — 24V Coil OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240SDFA0AAAA — 24V Coil OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240SDFA0AAAA — 24V Coil OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online