Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS240LTAA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS240LTAA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30 amp contactor with a 24V coil (part number 1171554) is the high-current switch that energizes the compressor and condenser fan on the ICP/Tempstar/Heil RGS240LTAA0AAAA system. When the thermostat calls for cooling, the 24V coil pulls the contacts closed to pass line voltage to the load. Pitted, welded, or chattering contacts cause failure to start, intermittent cooling, buzzing, or a unit that will not shut off. Replacing a worn contactor is one of the most common and reliable HVAC service repairs.

Specifications

Spec Value
Part Number 1171554 (CONTACTOR 2P 30A 24V)
Type 2-Pole Contactor
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Fitment OEM Replacement

Compatibility

Direct-fit replacement for the ICP RGS240LTAA0AAAA and related Tempstar/Heil/Comfortmaker units using a 2-pole 30A 24V coil contactor. Verify pole count, amp rating, and coil voltage against your existing part.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control/electrical access panel.
  3. Document — Photograph all line, load, and coil wire positions before disconnecting.
  4. Remove — Transfer wires one at a time, or unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each lead exactly per your photos.
  6. Test — Restore power and confirm the contacts pull in cleanly on a cooling call.

Signs You Need a Replacement

  • Buzzing or chattering when the unit tries to start
  • Burned, pitted, or welded contacts
  • Compressor or fan that will not start or will not shut off
  • Intermittent cooling with no thermostat fault

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240LTAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240LTAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240LTAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online