Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS240LSAA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS240LSAA0AAAA — 24V Coil | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite purpose contactor (part #1171554) is the electrical switch that energizes the compressor and condenser fan motor in your ICP RGS240LSAA0AAAA gas/electric package unit. Rated at 30 amps per pole with a 24-volt control coil, it closes when the thermostat calls for cooling, passing line voltage to the outdoor components. A failed contactor is one of the most common no-cooling service calls — symptoms include a humming outdoor unit that won't start, chattering contacts, or pitted, welded contacts that leave the compressor running continuously.

Specifications

Spec Value
Part Number 1171554
Type 2-Pole Definite Purpose Contactor
Brand ICP
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2

Compatibility

Direct-fit replacement for ICP / Tempstar / Heil RGS240LSAA0AAAA package units and compatible models in the RGS240 series sharing the same outdoor electrical assembly.

Installation Guide

  1. Safety First — Disconnect power at the breaker and pull the outdoor disconnect; verify zero voltage with a multimeter.
  2. Access — Remove the outdoor electrical access panel.
  3. Document — Photograph all wire positions before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil wires, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor/fan start on a cooling call.

Signs You Need a Replacement

  • Outdoor unit hums but compressor and fan won't start
  • Audible chattering or buzzing from the contactor
  • Burned, pitted, or welded contacts
  • Compressor runs continuously even when thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240LSAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240LSAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240LSAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online