Overview

This OEM definite-purpose contactor switches the high-voltage power to the compressor and condenser fan on the ICP / Tempstar / Heil RGS240HSEA0AAAA. When the thermostat calls and the 24V coil energizes, the contactor pulls in and closes its line-voltage contacts to start the equipment. The primary unit is a 2-pole 30A contactor (1171554) with a 24V coil; matched 3-pole 40A (1172449) and 3-pole 60A (1183142) variants are available for higher-capacity configurations. Pitted, welded, or chattering contacts are one of the most frequent causes of a no-start condition.

Specifications

Spec Value
OEM Part Numbers 1171554, 1172449, 1183142
Type Definite-Purpose Contactor
Brand ICP (Tempstar / Heil)
Primary Rating 2-Pole, 30A
Coil Voltage 24V
Alternate Ratings 3-Pole 40A, 3-Pole 60A
Fitment OEM Direct Replacement

Compatibility

Direct-fit OEM replacement for the ICP/Tempstar/Heil RGS240HSEA0AAAA and shared-platform RGS-series condensing units. Match pole count and amp rating to your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the service panel to expose the contactor.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and detach each wire, then unscrew the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect every wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor/fan start.

Signs You Need a Replacement

  • Buzzing or chattering contactor that won't pull in cleanly
  • Pitted, burnt, or welded-together contacts
  • Compressor and condenser fan fail to start on a cooling call
  • Visible arcing or melted contactor housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240HSEA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240HSEA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240HSEA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online