Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS240HRFA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS240HRFA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM definite-purpose contactor switches high-voltage power to the compressor and condenser fan motor on the ICP / Tempstar / Heil RGS240HRFA0AAAA system. When the 24V control circuit energizes the coil, an electromagnet pulls the contacts closed and delivers line voltage to the outdoor unit. Three OEM ratings are offered to match your equipment: part 1171554 (2-pole 30A 24V), 1172449 (3-pole 40A 24V) and 1183142 (3-pole 60A 24V). Contactors wear out from millions of switching cycles — pitted or welded contacts, a buzzing or chattering coil, and an outdoor unit that won't start (or won't stop) are the telltale symptoms. A fresh OEM contactor restores clean, reliable switching and protects the compressor from voltage drop and arcing damage.

Specifications

Spec Value
Part Numbers 1171554 (2P 30A), 1172449 (3P 40A), 1183142 (3P 60A)
Type Definite-Purpose Contactor
Brand ICP (Tempstar / Heil)
Coil Voltage 24V
Amp Ratings 30A / 40A / 60A
Poles 2-Pole & 3-Pole

Compatibility

Fits the ICP RGS240HRFA0AAAA and a wide range of Tempstar, Heil, Comfortmaker, and Arcoaire condensing units. Confirm pole count and amp rating on your existing contactor before ordering — match 2P/3P and 30/40/60A to the original.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, verify zero voltage with a multimeter.
  2. Access — Remove the condenser unit electrical access panel.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, then unbolt the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each lead exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts.
  • Loud buzzing or chattering from the coil.
  • Outdoor unit won't start, or won't shut off.
  • Visible arcing or melted housing around the terminals.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240HRFA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240HRFA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240HRFA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online