Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS214STAA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS214STAA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp contactor (part number 1171554) is the electrically-controlled switch that energizes the high-voltage circuit in your ICP/Heil/Tempstar RGS214STAA0AAAA system. Its 24-volt coil is pulled in by the low-voltage control circuit; when energized, the contactor closes its two sets of line-voltage contacts to power the compressor and/or fan motor. Over time the contacts pit, burn, and weld due to constant arcing, while the coil can open or stick. Common failure symptoms include a humming or chattering relay, contacts that won't pull in, a unit that won't start, or contacts that stay welded so the equipment never shuts off. Replacing a worn contactor restores reliable, safe switching.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP (Heil / Tempstar / Comfortmaker)
Fitment OEM Replacement

Compatibility

Engineered as a direct OEM replacement for the ICP/Heil/Tempstar RGS214STAA0AAAA and related International Comfort Products equipment that use a 2-pole 30A 24V definite-purpose contactor. Always confirm the existing contactor's pole count, amp rating, and coil voltage against your old part before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the service panel to expose the contactor.
  3. Document — Photograph all line and coil wiring before disconnecting anything.
  4. Remove — Label and transfer each wire one at a time, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the coil pulls in and the contacts close cleanly with no chatter.

Signs You Need a Replacement

  • Loud buzzing, humming, or chattering from the contactor.
  • Pitted, blackened, or welded contacts.
  • Unit won't start or fails to shut off.
  • Coil reads open or out of spec on a meter.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS214STAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS214STAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS214STAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online