Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS214SFAA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS214SFAA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole, 30-amp contactor (part number 1171554) with a 24-volt coil, built for the ICP/Tempstar/Heil RGS214SFAA0AAAA heat pump system. The contactor is an electrically operated switch that energizes the compressor and condenser fan motor whenever the 24V control signal calls for cooling or heat-pump operation. When the coil fails, the contacts pit, or the points weld shut, the outdoor unit either won't start or won't shut off. A 30A rating provides the headroom needed for reliable compressor inrush current, and the 24V coil matches the standard low-voltage control circuit on this equipment.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Brand ICP
Poles 2-Pole
Amp Rating 30A
Coil Voltage 24V

Compatibility

Designed for the ICP/Tempstar/Heil/Comfortmaker RGS214SFAA0AAAA and compatible 2-stage outdoor units that use a 2-pole 30A definite purpose contactor with a 24V coil. Always confirm the existing contactor's pole count, amp rating, and coil voltage before replacing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the outdoor unit's electrical service panel.
  3. Document — Photograph all line and load wires before disconnecting.
  4. Remove — Note the line-side and load-side terminals, the 24V coil wires, then disconnect and unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and the compressor/fan energize.

Signs You Need a Replacement

  • Outdoor unit hums but compressor and fan won't start
  • Burned, pitted, or welded contacts
  • Chattering or buzzing from the contactor
  • Unit won't shut off when the call ends

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS214SFAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS214SFAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS214SFAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online