Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS213SSEA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS213SSEA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite purpose contactor (P/N 1171554) is the electrical switch that energizes the high-voltage circuit in your ICP / Tempstar / Heil RGS213SSEA0AAAA system. When the 24-volt control signal hits the coil, the contactor pulls in and feeds line voltage to the compressor and condenser fan motor. Rated for 30 amps per pole with a 24V coil, it is one of the most common failure points in any HVAC system because it cycles thousands of times per season. Telltale failure symptoms include a unit that hums but won't start, pitted or welded contacts, a chattering buzz at the contactor, or a system that runs even after the thermostat is satisfied because the contacts have fused closed.

Specifications

Spec Value
Part Number 1171554
Type 2-Pole Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2

Compatibility

Direct OEM replacement for the ICP / Tempstar / Heil RGS213SSEA0AAAA and other RGS213-series units that use part number 1171554. Confirm your existing contactor is a 2-pole, 30A, 24V-coil unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and the local disconnect. Verify zero voltage with a multimeter before touching any wiring.
  2. Access — Remove the service/electrical panel to expose the contactor.
  3. Document — Photograph every wire and terminal position before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor, reconnect each wire exactly per your photo, and confirm the coil leads land on the 24V terminals.
  6. Test — Restore power and call for cooling/heating; verify the contactor pulls in cleanly with no chatter and the system starts.

Signs You Need a Replacement

  • Unit hums or buzzes but the compressor/fan won't start.
  • Burnt, pitted, or welded contact surfaces.
  • System keeps running after the thermostat is satisfied (stuck closed).
  • Visible arcing or a chattering noise when the unit cycles.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS213SSEA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS213SSEA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS213SSEA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online