Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS213SSAA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS213SSAA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole definite purpose contactor (P/N 1171554) for ICP, Heil, and Tempstar equipment. The contactor is the electromechanical switch that energizes the compressor and condenser fan motor when the thermostat calls for cooling. A 24V signal from the control transformer pulls in the coil, closing the 30-amp line-voltage contacts. When a contactor fails, the system either won't start, buzzes/chatters, or sticks closed and runs continuously. Pitted, welded, or burned contacts and a dead coil are the most common failure modes after years of high-current arcing.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V

Compatibility

Fits ICP / Heil / Tempstar / Comfortmaker condensing units and heat pumps using model RGS213SSAA0AAAA. As a definite purpose 2-pole 30A/24V contactor, it is a direct OEM replacement for the original switching component in this unit.

Installation Guide

  1. Safety First — Disconnect power at the breaker and pull the outdoor disconnect; verify zero voltage with a multimeter.
  2. Access — Remove the condenser service/electrical panel.
  3. Document — Photograph all wire positions before disconnecting.
  4. Remove — Transfer one wire at a time, or label each wire, then unscrew the old contactor from the mounting rail.
  5. Install — Mount the new contactor, reconnect line, load, and 24V coil leads exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and the compressor/fan start.

Signs You Need a Replacement

  • Unit won't start or only starts when you press the contactor in manually
  • Loud buzzing, humming, or chattering at the contactor
  • Visibly pitted, burned, or welded contacts
  • Compressor runs nonstop because contacts are stuck closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS213SSAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS213SSAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS213SSAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.