Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS213SREA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS213SREA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole definite purpose contactor (OEM part #1171554) for the ICP/Tempstar/Heil RGS213SREA0AAAA gas furnace and packaged unit. The contactor is the electromechanical switch that energizes the compressor and condenser fan motor when the 24V control circuit calls for cooling. Rated at 30 amps with a 24-volt coil, it handles the high-current load that the low-voltage thermostat circuit cannot switch directly. When a contactor fails, you may hear chattering or buzzing, see pitted or welded contacts, or find the outdoor unit will not start even though the thermostat is calling. Replacing a worn contactor restores reliable starting and protects the compressor from low-voltage and chatter-induced damage.

Specifications

Spec Value
OEM Part Number 1171554
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30 Amp
Coil Voltage 24V
Fits Model RGS213SREA0AAAA

Compatibility

Designed for the ICP/Tempstar/Heil/Comfortmaker RGS213SREA0AAAA and related RGS-series equipment. As a definite-purpose 2-pole 30A/24V contactor it is a common service replacement across many residential split and packaged systems — always confirm the existing contactor's pole count, amp rating, and coil voltage before installing.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel from the condensing/packaged unit.
  3. Document — Photograph all line, load, and coil wires before disconnecting.
  4. Remove — Label and remove wires from the old contactor, then unscrew it from the mounting bracket.
  5. Install — Mount the new contactor, then reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and verify the contactor pulls in cleanly on a cooling call with no chatter.

Signs You Need a Replacement

  • Buzzing, humming, or chattering from the outdoor unit
  • Pitted, burnt, or welded contacts
  • Compressor and fan won't start despite a cooling call
  • Contactor will not pull in or drop out reliably

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS213SREA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS213SREA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS213SREA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online