Overview

This OEM 2-pole, 30-amp definite purpose contactor (part #1171554) is the switching relay that energizes the compressor and condenser fan motor in your ICP/Tempstar/Heil RGS213SRCA0AAAA system. When the 24V control signal reaches the coil, the contactor pulls in and closes the line-voltage contacts that feed the outdoor unit. Contactors are a high-wear component — the contacts arc every time the system cycles, and over thousands of cycles they pit, burn, weld, or chatter. A failing contactor causes a unit that won't start, buzzing at the outdoor unit, or a compressor that runs continuously because the contacts have welded shut.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Brand ICP / Tempstar / Heil

Compatibility

Direct OEM fit for the ICP RGS213SRCA0AAAA and matching Tempstar, Heil, and Comfortmaker condensing units that use the 1171554 contactor. Always confirm the existing contactor's pole count, contact amperage, and 24V coil before replacing.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the condenser service/electrical panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer one wire at a time to the new contactor, or label each lead, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor, reconnect line and load on the correct poles and the two 24V coil leads per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call for cooling and the compressor/fan energize.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but won't start
  • Pitted, burnt, or blackened contacts
  • Compressor runs nonstop (welded contacts)
  • Chattering or rapid clicking at the contactor

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS213SRCA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS213SRCA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS213SRCA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online