Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS210SFCA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS210SFCA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 2-pole, 30-amp definite-purpose contactor (part 1171554) with a 24V coil is the main switching relay for the ICP Tempstar/Heil RGS210SFCA0AAAA package unit. When the thermostat calls for cooling, the control board energizes the 24VAC coil, pulling in both line-voltage poles to power the compressor and condenser fan motor. A failing contactor is one of the most frequent no-cool service calls: pitted or welded contacts can prevent startup or keep the compressor running after the call ends, while a burned coil leaves the unit completely dead on a cooling demand. Buzzing, chattering, or visibly burned contacts all point to replacement.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor, 2-Pole
Brand ICP / Tempstar / Heil
Contact Rating 30 A
Coil Voltage 24 VAC
Poles 2 (Double Pole)
Fit OEM Replacement

Compatibility

Built for the ICP Tempstar/Heil RGS210SFCA0AAAA and other RGS210-series condensing units using the 1171554 2-pole 30A contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel to expose the contactor.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, or unscrew the contactor from its bracket after labeling.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm both poles pull in and the compressor and fan start on a cooling call.

Signs You Need a Replacement

  • Unit won't start on a cooling call (open or burned coil)
  • Compressor keeps running after the thermostat is satisfied (welded contacts)
  • Loud buzzing or chattering from the contactor
  • Visibly pitted, melted, or carbon-tracked contacts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS210SFCA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS210SFCA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS210SFCA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online