This genuine OEM 2-pole, 30-amp definite purpose contactor (part #1171554) uses a 24V control coil to switch line-voltage power to the compressor and condenser fan. When the thermostat calls for cooling, the 24V coil pulls the contacts closed and energizes the outdoor unit. Contactors fail from arcing, pitted or welded contacts, insects, and coil burnout. Symptoms include a unit that won't start, a humming contactor that won't pull in, or a condenser that won't shut off because the contacts have welded together.
| Spec | Value |
|---|---|
| Part Number | 1171554 |
| Type | Definite Purpose Contactor |
| Brand | ICP / Heil / Tempstar |
| Contact Rating | 30A |
| Coil Voltage | 24 VAC |
| Poles | 2-Pole |
Factory-correct replacement for ICP/Heil/Tempstar model RGS210SDEA0AAAA and related systems using a 2-pole 30A contactor with a 24V coil. Verify amperage, pole count, and coil voltage against your existing contactor before installing.