Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS210SDAA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS210SDAA0AAAA — 24V Coil | Ships Today

SKU: 1171554-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole, 30-amp contactor with a 24-volt coil (part number 1171554) for the ICP / Tempstar / Heil RGS210SDAA0AAAA. The contactor is the high-current switch that energizes the system's line-voltage loads whenever the 24V control circuit calls for operation. When the thermostat sends a 24V signal, the coil pulls the contacts closed, sending power through both poles; when the call ends, a spring opens the contacts. Over thousands of cycles the silver contacts pit, corrode, and eventually weld or fail to close, causing no operation, chattering, or a system that won't shut off. A fresh OEM contactor restores clean, reliable switching and full rated current capacity.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fitment OEM Replacement

Compatibility

Direct-fit for the ICP RGS210SDAA0AAAA and widely shared across RGS-series and other ICP-family units sold under ICP, Tempstar, Heil, Comfortmaker and Arcoaire that use a 2-pole 30A 24V contactor. Confirm pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical/service panel.
  3. Document — Photograph every wire on the contactor before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect line, load, and 24V coil wires exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a call and drops out cleanly.

Signs You Need a Replacement

  • Loud buzzing, humming, or chattering when energized
  • Burned, pitted, or welded contacts
  • System won't start or won't shut off
  • Visible arcing or melted housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS210SDAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS210SDAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS210SDAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online