This OEM 2-pole definite-purpose contactor (part number 1178074) is the electromechanical switch that energizes the compressor and condenser fan in your ICP / Tempstar / Heil RGS150SECA0AAAA system. Rated for 30 amps with a 24-volt control coil, it closes its main contacts whenever the thermostat calls for cooling, sending line voltage to the outdoor unit. Contactors are one of the most common HVAC failure points: the silver contact points pit and burn from repeated arcing, and the coil can weaken until it no longer pulls in. Typical failure symptoms include a unit that hums but won't start, contacts that weld shut so the compressor never shuts off, chattering, or no outdoor unit operation at all.

Specifications

Spec Value
Part Number 1178074
Type Definite-Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole
Resistive Rating 30 Amps
Coil Voltage 24V
Fit OEM Replacement

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil RGS150SECA0AAAA furnace/condenser platform and other ICP-family units that originally shipped with part 1178074. Confirm your unit uses a 2-pole, 30A, 24V-coil contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and pull the outdoor disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to expose the contactor.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil wires; unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and the compressor/fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but won't start
  • Burned, pitted, or welded contact points
  • Compressor runs continuously and won't shut off
  • Chattering or intermittent cooling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150SECA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150SECA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150SECA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online