Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS150LSAA0AGAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS150LSAA0AGAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM definite-purpose contactor (part numbers 1178074 and 1178211) is the electromagnetic switch that controls high-voltage power to the compressor and condenser fan motor in your ICP RGS150LSAA0AGAA system. When the thermostat calls for cooling, the 24V control circuit energizes the coil, pulling the contacts closed to deliver line voltage to the load. The 1178074 is a 2-pole 30A unit; the 1178211 is a 2-pole 40A unit for higher-draw applications. Contactors are one of the most common HVAC failures — pitted, welded, or chattering contacts cause hard starts, buzzing, and units that won't shut off or won't start at all.

Specifications

Spec Value
OEM Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar / Comfortmaker
Poles 2-Pole
Contact Rating 30A / 40A
Coil Voltage 24V

Compatibility

Direct OEM fit for the ICP/Tempstar/Heil RGS150LSAA0AGAA furnace/condenser platform and compatible Comfortmaker and Day & Night equipment using the same definite-purpose contactor. Always match pole count, contact amperage, and 24V coil voltage to the failed unit.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, verify zero voltage with a multimeter across all terminals.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Transfer one wire at a time, or label leads, then unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect line, load, and 24V coil leads exactly per your photo.
  6. Test — Restore power and confirm the contacts pull in on a cooling call with no chatter.

Signs You Need a Replacement

  • Loud buzzing or humming from the contactor
  • Pitted, burned, or welded contacts
  • Compressor/fan won't start or won't shut off
  • Chattering or intermittent cooling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150LSAA0AGAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150LSAA0AGAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150LSAA0AGAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online