Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS121SECA0AAA – 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS121SECA0AAA – 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole, 30-amp definite purpose contactor with a 24V control coil (OEM #1178074) for ICP, Heil, and Tempstar HVAC equipment. The contactor is the main switching device that energizes the compressor and condenser fan motor: when the thermostat calls for cooling, 24V is applied to the coil, pulling the contacts closed to deliver line voltage to the load. Contactors are high-wear parts — their contacts pit and burn from repeated arcing, and the coil can fail open. Common failure symptoms include a system that won't start, contacts that weld closed (so the unit runs continuously), loud humming or chattering, and visible pitting or burn marks on the contacts.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Poles 2
Contact Rating 30 A
Coil Voltage 24 VAC

Compatibility

OEM replacement for the ICP/Tempstar/Heil RGS121SECA0AAA and related units using part 1178074. Confirm pole count (2-pole), amp rating (30A), and 24V coil match your existing contactor before ordering.

Installation Guide

  1. Safety First – Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access – Remove the unit's electrical access panel.
  3. Document – Photograph every line, load, and coil wire before disconnecting.
  4. Remove – Transfer wires one at a time or label them, then unscrew the old contactor from the mounting plate.
  5. Install – Mount the new contactor and reconnect each wire exactly per your photo, torquing terminals snugly.
  6. Test – Restore power, run a cooling call, and confirm the contactor pulls in and the compressor/fan energize.

Signs You Need a Replacement

  • Compressor and condenser fan won't start on a cooling call.
  • Pitted, burned, or welded contacts.
  • Loud humming, buzzing, or chattering from the contactor.
  • System runs continuously and won't shut off (stuck contacts).

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121SECA0AAA – 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121SECA0AAA – 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121SECA0AAA – 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online