Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS121LEAB0AAAA – 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS121LEAB0AAAA – 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM definite-purpose contactor (part #1178074) is a 2-pole, 30 amp device with a 24-volt control coil used in the ICP / Heil / Tempstar RGS121LEAB0AAAA system. The contactor acts as the high-voltage switch that energizes the compressor and condenser fan motor when the 24V control signal closes the coil. Contactors are high-wear components: the contacts arc every time they pull in, eventually pitting, welding shut, or burning open. A failed contactor is one of the most common causes of a system that won't start, won't shut off, or chatters at the relay.

Specifications

Spec Value
Part Number 1178074
Type Definite-Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amp
Coil Voltage 24V
Brand ICP (Heil / Tempstar)
Fit OEM exact-fit

Compatibility

Built for the ICP RGS121LEAB0AAAA and shared across ICP-family (Heil, Tempstar, Comfortmaker) equipment using a 2-pole 30A / 24V coil contactor. Verify part #1178074 and coil voltage against your unit before installing.

Installation Guide

  1. Safety First – Disconnect all power at the disconnect and breaker. Verify zero voltage on the line terminals with a multimeter.
  2. Access – Remove the electrical/service panel to expose the contactor.
  3. Document – Photograph every wire and terminal position before disconnecting.
  4. Remove – Label and disconnect line, load, and 24V coil wires; unfasten the old contactor from its bracket.
  5. Install – Mount the new contactor and reconnect each wire to the matching terminal per your photos.
  6. Test – Restore power and confirm the contactor pulls in on a call, energizes the load, and releases cleanly when the call ends.

Signs You Need a Replacement

  • Burned, pitted, or welded contacts
  • Compressor/fan won't start or won't shut off
  • Buzzing, humming, or chattering at the contactor
  • Coil clicks but contacts don't pass voltage to the load

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121LEAB0AAAA – 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121LEAB0AAAA – 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121LEAB0AAAA – 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online