Overview

This OEM 2-pole, 30-amp definite-purpose contactor (part #1178074) with a 24V coil is the main switching relay for the ICP / Heil / Tempstar RGS121LDCA0AAA. When the thermostat calls, the 24-volt coil pulls in the contacts to send line voltage to the compressor and condenser fan motor. Contactors are a high-wear item — every cycle arcs the contacts, and over years they pit, burn, weld shut, or fail to pull in. Symptoms include a system that won't start, a buzzing or chattering contactor, contacts welded so the compressor won't shut off, or visible pitting and burn marks on the contact pads. Replacing it restores clean, reliable switching and protects the compressor from low-voltage and chatter damage.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24 VAC
Fitment OEM Direct Replacement

Compatibility

Fits the ICP/Heil/Tempstar RGS121LDCA0AAA and any system specifying a 2-pole, 30A, 24V definite-purpose contactor. Match poles, amp rating, and coil voltage to your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the control-panel service cover.
  3. Document — Photograph all line, load, and 24V coil wire positions before disconnecting.
  4. Remove — Label and remove the wires, then unbolt the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a call and the compressor/fan start normally.

Signs You Need a Replacement

  • System won't start or starts intermittently
  • Loud buzzing, humming, or chattering at the contactor
  • Contacts welded closed so the unit won't shut off
  • Pitted, burned, or corroded contact pads

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121LDCA0AAA — OEM 24V Coil Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121LDCA0AAA — OEM 24V Coil Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121LDCA0AAA — OEM 24V Coil Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online