Overview

This OEM 2-pole, 30-amp contactor with a 24-volt control coil (part 1178074) is the electrical switch that energizes the line-voltage components of the ICP Tempstar/Heil RGS121LDBA0AAAA. When the control circuit applies 24V to the coil, the contactor pulls in and closes its 30A contacts, sending power to the connected load; when the call ends, the coil de-energizes and the contacts open. Contactors are high-cycle wear items — their contacts pit, burn, and weld over time, and the coil can fail open. A worn contactor causes chattering, intermittent operation, or a unit that won't start at all.

Specifications

Spec Value
Part Number 1178074
Type Definite purpose contactor, 2-pole
Brand ICP (Tempstar / Heil)
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Fits Model RGS121LDBA0AAAA

Compatibility

Designed for the ICP Tempstar/Heil RGS121LDBA0AAAA and other units specifying a 2-pole, 30A, 24V-coil contactor. Confirm pole count, amp rating, and 24V coil against your unit's wiring diagram and data label before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and unit switch; verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control compartment service panel.
  3. Document — Photograph every wire and terminal on the existing contactor.
  4. Remove — Transfer wires one at a time, or label them, then unbolt and remove the old contactor.
  5. Install — Mount the new 2-pole 30A contactor and reconnect line, load, and 24V coil wires per your photo.
  6. Test — Restore power, initiate a call, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Buzzing, humming, or chattering from the contactor.
  • Pitted, burned, or welded-together contacts.
  • Unit fails to start or starts intermittently.
  • Coil does not pull the contacts in on a 24V call.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121LDBA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121LDBA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121LDBA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.