OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM 2-pole, 30-amp contactor with a 24V coil (part 1178074) switches line-voltage loads in the ICP/Heil/Tempstar RGS120SEAA0AAA system. When the 24V coil is energized by the control circuit, the contactor pulls in and closes both poles to power the load; when the call ends, it drops out and breaks the circuit. Contactors wear out as the contacts pit, burn, and weld from the inrush current of each cycle, and the coil can fail open or buzz. Symptoms include a system that will not start, chattering at the contactor, or contacts that stay closed after the thermostat is satisfied. A genuine OEM 30A contactor restores clean, reliable switching and protects downstream components.
| Spec | Value |
|---|---|
| Part Number | 1178074 |
| Type | 2-Pole Contactor |
| Brand | ICP (Heil / Tempstar / Comfortmaker) |
| Coil Voltage | 24V |
| Contact Rating | 30A |
| Poles | 2 |
| Fitment | OEM |
Designed for the ICP/Heil/Tempstar RGS120SEAA0AAA unit and related models using a 2-pole 30A contactor with a 24V coil. Confirm coil voltage, amp rating, and pole count against your existing contactor before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.