Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS120LTAB0AAA — 24V Coil OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS120LTAB0AAA — 24V Coil OEM 1178074 | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine ICP OEM 2-pole, 30-amp contactor with a 24V coil (part number 1178074) for the RGS120LTAB0AAA system. The contactor is the electromechanical switch that energizes the high-voltage loads — the compressor and condenser fan motor — whenever the 24V control circuit calls for them. Over time the contacts pit, weld, or burn, and the coil can fail, leaving the unit unable to start, stuck running, or chattering. Replacing the contactor with a genuine OEM 30A unit restores clean, reliable switching and protects the compressor from damaging electrical conditions.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP (Heil / Tempstar / Comfortmaker)
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Fits Model RGS120LTAB0AAA
Fitment OEM Direct Replacement

Compatibility

Direct-fit replacement for the 2-pole 30A 24V-coil contactor used in the ICP / Heil / Tempstar / Comfortmaker RGS120LTAB0AAA system. Verify pole count, amp rating, and 24V coil match before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer one wire at a time or label each, then unbolt the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect every wire to the matching terminal per your photos.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor and fan energize.

Signs You Need a Replacement

  • Unit will not start or compressor stays off on a cooling call.
  • Loud chattering, buzzing, or humming at the contactor.
  • Contacts that are pitted, burnt, or welded shut.
  • System runs continuously and will not shut off.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120LTAB0AAA — 24V Coil OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120LTAB0AAA — 24V Coil OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120LTAB0AAA — 24V Coil OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online